Case study

Multipart Rooflight Provides Pool Room With An Abundance of Natural Light

pool underneath skylight
Overview

Glazing Vision collaborated with A R C Architecture and Matrod Frampton Ltd to install a large flat rooflight in a Lymington pool room extension for natural light and tranquility, along with a loft rooflight for daylight and ventilation.

Details

Architect

A R C Architecture Ltd

Contractor

Matrod Frampton Ltd

Images

Jonathan Gooding
zoomed into skylight

The Brief

Glazing Vision’s Flushglaze Fixed Multipart Rooflight in Slate Grey Matt was specified for the roof of the pool house, which was an impressive 3800mm x 10360mm in size, which almost mirrors the size of the swimming pool below.

Bespoke glass was selected for this particular project. The double-glazed outer pane was made up of heat soak tested, toughened glass which offers a greater resistance to thermal stresses and provides better protection against glass breaking, reducing risk of injury, essential with a pool directly below.

Argon gas filled the space between the panes of glass which helps insulate the room and minimises the transfer of heat through the glass along with a black warm edge spacer which is an insulating plastic composite material that becomes a barrier to heat loss.

an open skylight on roof

The Solution

The inner pane consisted of heat soak tested, toughened, PVB laminated glass which prevents glass shattering under impact by holding the shards together on the membrane so they cannot become lethal, and includes a soft coat low E rating of 1.1, helping with the energy efficiency of the room by reducing energy costs.

The product was tested to class 1 in accordance with CWCT TN66/67 which is essential for rooflights which might be walked on for occasional cleaning/ maintenance activities, and which will therefore need to support both the weight of people on the glass and their equipment, which may be required on this occasion.

The rooflight was supplied in 6 sections with internal back-to-back angles at the joints between each section. The 6 sections were sized to achieve an equal split when viewed from underneath.

Our Skydoor Electric Hinged Access Rooflight was specified on the roof of the loft space which is ideal for ventilation and regular access, and offers natural daylight to the space below. Intelligent actuators ensure synchronized operation between the two supporting mechanisms, so the Skydoor opens to a maximum 87° in one fluid, trouble-free motion, providing you with easy access to the space above.

hinged skylight on roof

The Details

The glass was a double-glazed unit comprising of a heat soak tested, toughened, soft coat low E (1.1) outer pane, with Argon Gas within the space between the panes and black warm edge spacer, with the inner pane consisting of heat soak tested, toughened, PVB Laminated glass, and was also tested to class 1.

Both the hinged access rooflights and the fixed rooflights were expertly installed by our sister brand, Glazing Renovations.

“Glazing Vision were helpful in explaining the two different upstands required for the different glazing systems. The installation team were helpful and carried out their work in a professional manor.” – Steve Davies, Site Manager, Matrod Frampton.

Working on a project which requires rooflights? Get in touch with our team of expert advisors who will be happy to assist you.

Talk to our Technical Specification Managers about your project

Our team will give you expert advice and guidance on:

  • The entire design and specification process

  • Our product range, including key considerations and optional extras

  • Our bespoke service

Find an expert

We use this postcode to assign your local Technical Sales Manager

Technical Specification Manager details not found

We're sorry, but we couldn't find a Technical Specification Manager for this area.

We’ll find the best person for you to speak to and be in touch within one working day.

Thank you for your submission.

There is an issue with the information you have provided, please check the form and try again.