Our team will give you expert advice and guidance on the entire design and specification process including our extensive product range, including key considerations and optional extras and our dedicated bespoke service
Elevate Your Space with Every Step
Whether you require a solution for your roof terrace, balcony, or rooftop garden, the Glazing Vision Flushglaze Walk-On Rooflight provides the ultimate combination of durability and aesthetics for any property, allowing natural daylight to flow into the room(s) below without compromising usable space.
Constructed from toughened laminated glass, the Flushglaze Walk-On Rooflight is manufactured to withstand regular foot traffic in UK domestic applications with uniform loading’s of 1.5kN/m² and concentrated loading’s of 2.0kN in accordance with EN 1991-1-1-1:2002.
The Flushglaze Walk On Rooflights are commonly installed using decking to achieve a flush finish with the rooflight as an upstand is still required.
Selected sizes of this product are available to buy immediately on our online shop.
Buy now on rooflights.comKey features
Optional extras
Specification
Min Span |
400mm |
Max Span |
4131mm |
Min Width |
400mm |
Max Width |
4131mm |
Min upstand pitch |
1 degree |
Max upstand pitch |
70 degrees |
Glazing Vision recommends a pitch of 1 degree for standard units.
Note that the minimum and maximum span, width and pitch are dependent on various factors, your technical sales advisor will be happy to advise on these. Further information on upstand requirements and product dimensions can be found on our website or by contacting your technical sales advisor.
Structural integrity of the Flushglaze Walk On Rooflight is assured through the use of finite element analysis (FEA) and testing. Further information and specific performance details can be obtained from your Technical Sales Advisor. The Walk On Flushglaze Rooflight has been thoroughly tested and achieved the following classification results:
Size: 2000 mm span x 2500 mm width, Pitch: 0°
Air Permeability - EN 12207 - Class 4 + 600Pa
Water Tightness - EN 12208 - Class 9A 600Pa
The Flushglaze Walk On Rooflight has been expertly designed with security as a priority - The product is tested to LPS2081 Issue 1:2015, approved by the Loss Prevention Certification Board (Cert/LPCB ref: 1347a) and Secured by Design.
To achieve Security Rating A, the inner pane must be at least 8.8 mm PVB laminated glass (two 4 mm thick panes separated by an 0.8 mm thick PVB interlayer).
To achieve Security Rating B, the inner pane must be at least 9.5 mm ionomer laminated glass (two 4 mm thick panes separated by a 1.5 mm thick ionomer interlayer).
Please contact our team if you have off-spec requirements for dimensions, glass or anything else, we’ll be happy to assist
Standards
Awards and certifications

Made in Britain
Glazing Vision rooflights are assembled on site in our rural Norfolk factory to ensure a high quality product - Made in Britain, trusted internationally.

ISO 9001 & ISO 14001
Glazing Vision operates to BSI ISO9001 and ISO14001 standards to ensure high quality rooflights

Secured by Design
Glazing Vision rooflights have been extensively tested and Secured by Design

Approved by the BBA
Glazing Vision rooflights have been approved by the BBA, with our Flushglaze Rooflight being the first flat rooflight ever approved by BBA

Approved by the LPCB
Glazing Vision Rooflights have been approved by the Loss Prevention Certification Board, allowing them to meet enhanced security requirements.

QualiCoat Applicator
Glazing Vision rooflights feature QualiCoat approved aluminum framework to ensure a high quality paint finish
Compare with other products
Access
Fire rated
Flat roof
Pitched roof
Residential
Ventilation
Walk on

Flushglaze Walk On Rooflight

Flushglaze Fixed Rooflight

Flushglaze Fixed Multipart Rooflight

Flushglaze Wall Abutted Rooflight

Flushglaze Eaves Rooflight

Flushglaze Internal Walk On Rooflight
Manuals & guides
CAD & BIM
Frequently Asked Questions
Yes, you will still require an upstand for the Flushglaze Walk On Rooflight, you will need to construct your upstand with a minimum thickness of 100mm and a minimum height of 150mm.
The Glazing Vision Walk On Rooflight can withstand regular foot traffic in UK domestic applications with uniform loadings of 1.5kN/m² and concentrated loadings of 2.0kN.
The Glazing Vision Flushglaze Walk On Rooflight is required to be installed at a 1 degree pitch to facilitate water runoff.
Glass can become slippery when wet therefore applying an anti-slip glass surface finish to the glass should always be considered to ensure the safety of all people using the walk on rooflight. We commonly see sandblasted or fritted glass being specified for slip resistance.
Lead times vary per product as they are carefully assembled and tested in-house, but your local Technical Sales Manager can advise you of our latest lead times.
Our flat rooflights are measured by their External Kerb Dimensions, which refer to the distance between the external of the kerb to the external of the kerb on all sides.